Table of Contents
UHD will automatically select the USRP-Embedded FPGA image from the installed images package. The FPGA image selection can be overridden with the --fpga= device address parameter.
Example device address string representations to specify non-standard FPGA image:
fpga=usrp_e100_custom.bin
The master clock rate of the USRP-Embedded feeds both the FPGA DSP and the codec chip. Hundreds of rates between 32MHz and 64MHz are available. A few notable rates are:
To use the 61.44MHz clock rate with the USRP-Embedded, two jumpers must be moved on the device.
Note: See instructions below to communicate the desired clock rate UHD.
To use other clock rates, the jumpers will need to be in the default position.
To communicate the desired clock rate into UHD, specify the a special device address argument, where the key is master_clock_rate and the value is a rate in Hz. Example:
uhd_usrp_probe --args="master_clock_rate=52e6"
The E1xx has a 10MHz TCXO which can be used to discipline the flexible clocking by selecting REF_INT for the clock_config_t.
Alternately, an external 10MHz reference clock can be supplied by soldering a connector.
An exteral PPS signal for timestamp synchronization can be supplied by soldering a connector.
Test the PPS input with the following app:
cd <install-path>/share/uhd/examples ./test_pps_input --args=<args>
Please see the Internal GPSDO Application Notes for information on configuring and using the internal GPSDO.
UHD will always try to detect an installed GPSDO at runtime. There is not a special EEPROM value to burn for GPSDO detection.
The LEDs on the front panel can be useful in debugging hardware and software issues. The LEDs reveal the following about the state of the device:
The following sensors are available; they can be queried through the API.